KoldLok® Grommets prevent costly bypass airflow, reduce hotspots, and improve the PUE of your data center. Immediately increase the efficiency of your entire cooling system with this simple solution that delivers quick payback and long term energy cost savings.
Your IT equipment is generating more heat than ever and the cost to cool that equipment is increasing. According to The Uptime Institute, Inc.® electricity consumed by IT equipment is the primary driver of data center operating costs. Based on measurements at multiple data centers, 50 - 80% of valuable conditioned air is not reaching the air intake of IT equipment due to unsealed cable openings. This lost air, known as bypass airflow, contributes to equipment hot spots, cooling unit inefficiencies, and increasing operating costs. The fastest and easiest way to save money is to seal your cable openings.
The KoldLok® Grommet is a superior sealing solution that increases current cooling unit capacity, mitigates equipment heat loads, and raises static pressure under the raised floor to improve cool air delivery through perforated tiles or floor grates.
Benefits
Superior Sealing: Multiple layers of different length, opposing brush filaments eliminate up to 98% of bypass airflow
Install it and forget it: Will not become dislodged and requires no additional maintenance
Easy Installation: Tool-less installation, requires no downtime to install or recable
KoldLok Return on Investment - Review the features of KoldLok® that make it the brush grommet with the lowest cost of ownership and highest energy dollar savings on the market.
Financial Impact Study - This study shows how KoldLok Grommets provide a fast return on investment in small and large data centers, whether new construction or existing facilities.
Click here to find a KoldLok Reseller in your area

KoldLok® Grommets optimize energy efficiency in data centers and are Energy Star rated.
MiniItem Number 10077 - MSRP $44.00 USD
Item Number 10052 - MSRP $48.00 USD
Specification Sheets | Install Guide | Product Illustrations
 |
| 10052 and 10077 |
Applications
Designed to seal small cable openings in the raised floor of new or existing computer rooms.
| Item No. 10077 |
US unit of measure (Inches) |
Metric (mm) |
| Usable Cable Area |
5 x 2 1/2 |
127 x 64 |
| To install Grommet in interior of the tile |
4 x 6 |
102 x 152 |
| To install long side of the Grommet on the tile edge |
5 x 6 |
127 x 152 |
| To install short side of the Grommet on the tile edge |
4 x 7 |
102 x 179 |
Special Features
- Smaller size offers flexibility for data centers that have multiple cable opening sizes
- Meets smaller cable opening standards specified in new data center builds
- Cost-effective method of separating data cabling from power cabling
- Impact-resistant and durable
- Contains no loose or partially fastened parts that can become separated or fall through the raised floor
- Satisfies NFPA 75 Section 5-4.4 requirement by self-dressing the raw metal edges of raised-floor tile cable openings
- Compliant with the directive that restricts the use of certain hazardous substances in electrical and electronic equipment (RoHS)
IntegralItem Number 1010 - Integral - MSRP $79.00 USD
Item Number 3030 - Split Integral - MSRP $84.00 USD
Specification Sheets | Install Guide | Product Illustrations
 |
 |
| 1010 |
3030 |
Applications
Airflow management device designed to seal cable openings in new raised-floor systems prior to the installation of communication or power cabling.
| Item No. 1010, 3030 |
US unit of measure (Inches) |
Metric (mm) |
| Usable Cable Area |
8 x 4
|
203 x 102
|
| To install Grommet in interior of the tile |
9 1/4 x 6 3/4 |
235 x 172 |
| To install long side of the Grommet on the tile edge |
9 1/4 x 7 1/2 |
235 x 191 |
| To install short side of the Grommet on the tile edge |
10 1/8 x 6 3/4 |
275 x 172 |
Special Features
- The Split Integral Grommets allow tiles to be moved without capturing cables
- The Grommets integrate with the raised-floor static dissipation system
- 32 square inch usable cabling area accommodates a variety of cabling requirements, including 100 amp power connectors
- The Grommets satisfy NFPA 75 Section 5-4.4 requirement by self-dressing the raw metal edges of raised-floor tile cable cutouts
- The Grommets contain no loose or partially fastened parts, which can become separated or fall through the raised floor.
- Compliant with the directive that restricts the use of certain hazardous substances in electrical and electronic equipment (RoHS)
Surface MountItem Number 2020 - Surface Mount - MSRP $89.00 USD
Item Number 2030 - Surface L - MSRP $104.00 USD
Item Number 2040 - Surface XL - MSRP $114.00 USD
Specification Sheets | Install Guide | Product Illustrations
Applications
Designed to seal a variety of existing raised-floor tile cutouts and allow the flexibility of removing tiles without capturing cables. Item Nos. 2030 and 2040 allow for larger sealing capacities.
| Item No. 2020 |
US unit of measure (Inches) |
Metric (mm) |
| Maximum cutout size sealed |
10 x 7 |
254 x 184 |
| Usable cable Area |
8 x 4 |
210 x 102 |
| Item No. 2030 |
|
|
| Maximum cutout size sealed |
10 x 9 |
254 x 248 |
| Usable cable area |
8 x 4 |
210 x 102 |
| Item No. 2040 |
|
|
| Maximum cutout size sealed |
10 x 13 |
254 x 330 |
| Usable cable area |
8 x 4 |
210 x 102 |
Special Features
- The Surface Mount Grommet facilitates re-cabling and allows tiles to be moved without capturing cables
- The Grommets integrate with the raised-floor static dissipation system, providing 1 GigaOhm of resistance.
- The Grommets contain no loose or partially fastened parts, which can become separated or fall through the raised floor.
- Compliant with the directive that restricts the use of certain hazardous substances in electrical and electronic equipment (RoHS)
ExtendedItem Number 10012 - MSRP $94.00 USD
Item Number 10013 - MSRP $99.00 USD
Specification Sheets | Install Guide | Product Illustrations
 |
 |
| 10012 |
10013 |
Applications
Designed to seal a variety of existing larger openings, with the added flexibility of modification for unique openings.
| |
US unit of measure (Inches) |
Metric (mm) |
| Item No. 10012 |
|
|
| Maximum cutout size sealed |
24 x 4 |
610 x 102 |
| Usable cable area |
22 x 2 1/2 |
559 x 66 |
Item No. 10013
|
|
|
Maximum cutout size sealed
|
24 x 7 |
610 x 178 |
Usable cable area
|
22 x 5 1/2 |
559 x 140 |
Special Features
- The Grommets can be modified to seal unique cable openings
- The Grommets integrate with the raised-floor static dissipation system
- Compliant with the directive that restricts the use of certain hazardous substances in electrical and electronic equipment (RoHS)
U.S. Patent No. 6,632,999 and International patents pending
|